By using our site you agree that we use cookies. More OK

DEK - Single-phase commutating chokes

DEG / DEK

Contact
Tel.: +43 / 2689 / 2744 0
E-mail: info@trafomodern.com

Designed and tested according

  • IEC/EN 61558-2-20

Typical applications

  • Inverter applications

CAD data

Basic equipment

  • Insulation class B
  • Ambient temperature 25 to 40 C
  • Connection terminal (<= 25 A)
  • Frequency 50/60 Hz
Here is a hidden table in the mobile version. Click here to display it.
ΔU = 9,2 V / phase
rated current
Inductivity
L
Type,
Order no.
Price
per unit
Cu-factor 1) Copper surcharge
A mH Euro Euro
6,5 4,51 DEK0,03-9,2
206954
54,30 0,15 0,75
13 2,25 DEK0,06-9,2
206955
59,60 0,25 1,25
22 1,33 DEK0,1-9,2
206956
73,70 0,30 1,50
35 0,84 DEK0,16-9,2
206957
99,00 0,40 2,01
44 0,67 DEK0,2-9,2
206958
110,80 1,00 5,01
54 0,54 DEK0,25-9,2
206959
115,80 1,00 5,01
69 0,42 DEK0,315-9,2
206960
135,80 1,20 6,02
87 0,34 DEK0,4-9,2
206961
144,30 1,30 6,52
109 0,27 DEK0,5-9,2
206962
156,50 1,40 7,02
137 0,21 DEK0,63-9,2
206963
202,90 2,00 10,03
174 0,17 DEK0,8-9,2
206964
218,80 2,30 11,53
217 0,13 DEK1,0-9,2
206965
253,10 3,00 15,04
285 0,103 DEK1,3-9,2
206966
365,50 4,00 20,06
350 0,084 DEK1,6-9,2
206967
432,20 4,50 22,56
440 0,067 DEK2,0-9,2
206968
564,70 5,00 25,07
550 0,053 DEK2,5-9,2
206969
593,90 5,50 27,58
650 0,045 DEK3,0-9,2
206970
920,30 10,80 54,15
870 0,034 DEK4,0-9,2
206971
1.108,40 11,00 55,15

1) The calculation method of the material price surcharge will be explained in Section 2.1 in the general conditions of busines

Here is a hidden table in the mobile version. Click here to display it.
ΔU = 9,2 V / phase
rated current
Inductivity
L
Type,
Order no.
Price
per unit
Cu-factor 2) Copper surcharge
A mH Euro Euro
3,7 13,76 DEK0,03-16
206976
54,30 0,15 0,75
7,5 6,79 DEK0,06-16
206977
59,60 0,25 1,25
12,5 4,07 DEK0,1-16
206978
65,50 0,30 1,50
20 2,54 DEK0,16-16
206979
80,20 0,40 2,01
25 2,03 DEK0,2-16
206984
94,50 1,00 5,01
31 1,64 DEK0,25-16
206985
115,80 1,00 5,01
38 1,34 DEK0,315-16
206986
116,50 1,20 6,02
50 1,01 DEK0,4-16
206987
140,40 1,30 6,52
62 0,82 DEK0,5-16
206988
150,40 1,40 7,02
78 0,65 DEK0,63-16
206989
176,00 2,00 10,03
100 0,51 DEK0,8-16
206990
193,20 2,30 11,53
125 0,407 DEK1,0-16
206991
227,30 3,00 15,04
160 0,318 DEK1,3-16
206992
286,10 4,00 20,06
200 0,254 DEK1,6-16
206993
397,20 4,50 22,56
250 0,203 DEK2,0-16
206994
497,40 5,00 25,07
310 0,164 DEK2,5-16
206995
526,80 5,50 27,58
375 0,135 DEK3,0-16
206996
920,30 10,80 54,15
500 0,101 DEK4,0-16
206997
1.009,40 11,00 55,15

DEK graphic - Single-phase commutating choke

Type Total
weight
Copper
losses
a a1 b b1 c c1 e f g Terminal Terminal
lug
kg W
DEK0,03 0,7 7 66 - 55 71 61 80 50 44 4,8 x 8 4 mm2 -
DEK0,06 1,5 7 84 - 60 87 75 103 64 47 4,8 x 8 10 mm2 -
DEK0,1 2 9 84 - 74 101 75 103 64 61 4,8 x 8 10 mm2 -
DEK0,16 2,3 14 84 - 83 98 75 - 64 70 4,8 x 8 - 15 x 2/7
DEK0,2 3 19 105 - 80 94 94 - 85 63 5,8 x 12 - 15 x 2/7
DEK0,25 3,8 16 105 - 88 102 94 - 85 71 5,8 x 12 - 15 x 2/7
DEK0,315 4,3 20 120 - 86 108 106 - 90 68 5,8 x 12 - 20 x 3/9
DEK0,4 5,2 21 120 - 98 120 106 - 90 80 5,8 x 12 - 20 x 3/9
DEK0,5 6,8 23 120 - 118 145 106 - 90 100 5,8 x 12 - 25 x 5/11
DEK0,63 7,7 29 150 - 104 132 132 - 122 82 7 x 15 - 25 x 5/11
DEK0,8 9,6 30 150 - 121 149 132 - 122 99 7 x 15 - 25 x 5/11
DEK1,0 13,4 31 150 - 147 192 132 - 122 125 7 x 15 - 40 x 5/14
DEK1,3 14,9 37 174 - 140 181 152 - 135 115 7 x 15 - 40 x 5/14
DEK1,6 17,4 46 192 - 146 186 170 - 150 116 10 x 18 - 40 x 5/14
DEK2,0 21,5 74 192 - 158 198 170 - 150 128 10 x 18 - 40 x 10/14
DEK2,5 21,5 78 192 - 158 198 170 - 150 128 10 x 18 - 40 x 10/14

all dimensions in mm


DEK graphic 2 - Single-phase commutating choke

Type Total
weight
Copper
losses
a a1 b b1 c c1 e f g Terminal Terminal
lug
kg W
DEK3,0 26 63 150 197 138 222 259 - 100 108 11 - 50 x 10/2 x 14
DEK4,0 35 97 150 197 163 242 259 - 100 133 11 - 50 x 10/2 x 14

all dimensions in mm

Phone Mail