DT - Three-phase matching transformers

Three-phase transformer: DT / DTZ / DTI / DSB (earthing autotransformer)

Contact
Tel.: +43 / 2689 / 2744 – 0
E-mail: info@trafomodern.com

Designed and tested according

  • IEC/EN 61558-2-1 / EN 60076-1
  • UL 5085-2
  • CSA 22.2 No. 66

For use according to

  • IEC/EN 60204-1

Typical applications

  • Voltage adjustment
  • Generation of four-wire networks based on three-wire network
  • Power transfer

Basic equipment

  • Separate windings
  • Insulation class B / F from 6.3 kVA
  • Ambient temperature –25 to 40 °C
  • Connection terminal (<=115 A)
  • Frequency 50/60 Hz
  • ±5 % tapping on the primary side

CAD data

  • Static shield windings is additional shielding between primary and secondary sides.
  • For versions with increased climate resistance, the transformers is supplied with a specially insulated finish.The finish enables the transformer to be used in areas of high humidity.
  • Transformer version with reinforced insulation upon request.
  • CUR according to UL-File XPTQ2.E168819 to 6,3 kVA (Transformers, General Purpose - Component bzw. Transformers, General Purpose Certified for Canada - Component)
  • CUR according to EIS 130 or EIS 155 to OBJY2. or OBJY8.E160829 (Systems, Electrical Insulation - Component bzw. Systems, Electrical Insulation Certified for Canada - Component)

When ordering, the following information must be added to the type designation:

DT0,1(*/*)*
1st place holder ≙ rated input voltage
2nd place holder ≙ rated output voltage
3rd place holder ≙ vector group

Sample order

  • requested type DT0,1
  • requested rated input voltage 1000 V
  • requested rated output voltage 12 V
  • requested vector group Dy(n)5

The correct type designation reads  DT0,1(1000/12)Dy(n)5

Higher outputs on request.
The unambiguous article number of your configuration will be defined by trafomodern during the offer- and order process

  Here is a hidden table in the mobile version. Click here to display it.
Type rating for use according to insulation class1) Rated input voltage Rated output voltage Type Price per unit Price for currents
up to
Cu-factor2) Copper surcharge
B kVA F kVA V (selectable) V (selectable)   Euro A   Euro
0,1 - 50-1000 12-1000 DT0,1(*/*)* 136,80 16 0,45 2,26
0,16 -     DT0,16(*/*)* 150,40   0,77 3,86
0,25 -     DT0,25(*/*)* 167,40   1,00 5,01
0,4 -     DT0,4(*/*)* 195,70   1,60 8,02
0,5 -     DT0,5(*/*)* 210,20   1,85 9,28
0,63 -     DT0,63(*/*)* 234,80   2,60 13,04
0,8 -     DT0,8(*/*)* 246,90   2,60 13,04
1 -     DT1,0(*/*)* 290,80   3,50 17,55
1,3 -   24-1000 DT1,3(*/*)* 325,10   4,00 20,06
1,6 -     DT1,6(*/*)* 359,40   5,00 25,07
2 -     DT2,0(*/*)* 406,90   6,30 31,59
2,5 -     DT2,5(*/*)* 474,30 25 7,00 35,10
3,2 -     DT3,2(*/*)* 512,00   10,50 52,64
4 -     DT4,0(*/*)* 663,60   11,00 55,15
5 -     DT5,0(*/*)* 799,30   13,00 65,18
6,3 -     DT6,3(*/*)* 906,70   15,00 75,21
8 9     DT8,0(*/*)* 1.250,40 63 16,00 80,22
10 11,2     DT10,0(*/*)* 1.547,80   27,00 135,37

1) Rated output when used according to insulation class B, maximum of 130° C; for insulation class F maximum of 155° C
2) The calculation method of the material price surcharge will be explained in Section 2.1 in the general conditions of busines


DT graphic - Three-phase matching transformer

Here is a hidden table in the mobile version. Click here to display it.
Type Total
weight
No-load
losses
Short-
circuit
losses
Short-
circuit
voltage
Efficiency
factor
a b b1 c c1 e f ø g
  kg W W %                  
DT0,1 0,9 5 18 14,8 0,81 105 91 66 128 82 80 50 5 x 8
DT0,16 1,9 6 30 15,5 0,82 125 86 61 148 102 100 45 5 x 8
DT0,25 2,5 9 35 10,9 0,85 125 96 71 148 102 100 55 5 x 8
DT0,4 3,6 11 45 10,1 0,88 155 97 77 168 128 130 57 8 x 12
DT0,5 5,1 17 40 6,7 0,9 155 112 92 168 128 130 72 8 x 12
DT0,63 6,1 19 50 7 0,9 190 102 82 194 155 170 58 8 x 12
DT0,8 7,5 25 50 5,8 0,91 190 112 92 194 155 170 68 8 x 12
DT1,0 8,9 35 55 5,1 0,92 190 122 102 194 155 170 78 8 x 12
DT1,3 11 35 70 5,1 0,93 210 122 107 213 174 175 87 8 x 12
DT1,6 12,9 45 70 4,1 0,93 210 132 117 213 174 175 97 8 x 12
DT2,0 20,1 55 85 3,9 0,93 240 124 107 247 208 185 85 10 x 18
DT2,5 22,4 65 95 3,6 0,94 240 134 117 247 208 185 95 10 x 18
DT3,2 27,7 30 135 4,2 0,94 300 116 106 296 260 224 78 10 x 18
DT4,0 31 35 130 3,2 0,96 300 132 122 296 260 224 94 10 x 18
DT5,0 39,6 75 145 2,5 0,97 300 157 147 296 260 224 119 10 x 18

all dimensions in mm

DT graphic 2 - Three-phase matching transformer

Here is a hidden table in the mobile version. Click here to display it.
Type Total
weight
No-
load
losses
Short-
circuit
losses
Short-
circuit
voltage
Efficiency
factor
a b b1 c c1 e f ø g
  kg W W %                  
DT6,3 45 80 145 2 0,97 300 193 162 334 260 224 134 10 x 18
DT8 55 50 215 4,2 0,97 390 184 152 384 310 350 126 10 x 18
DT10 70 55 280 3,5 0,97 390 199 167 384 310 350 141 10 x 18

all dimensions in mm