UTI - Single-phase multi-winding transformers

UTI: Single-phase multi-winding transformer

Contact
Tel.: +43 / 2689 / 2744 – 0
E-mail: info@trafomodern.com

Designed and tested according

  • IEC/EN 61558-2-2 / 2-4 / 2-6
  • UL 5085-2
  • CSA 22.2 No. 66

For use according to

  • IEC/EN 60204-1

Typical applications

  • Control voltage circuits
  • Functional low voltage
  • Protective separation

Basic equipment

  • Separate windings
  • Insulation class B
  • Ambient temperature –25 to 40 °C
  • Connection terminal (<=115 A)
  • Frequency 50/60 Hz

CAD data

CUR to UL-File XPTQ2. or XPTQ8. E168819 (Transformers, General Purpose - Component bzw. Transformers, General Purpose Certified for Canada - Component)
  Here is a hidden table in the mobile version. Click here to display it.
Rated output Short-time rating Rated input voltage Rated output voltage Type Price per unit Cu-factor1) Copper surcharge
(kVA) (kVA) V V   Euro   Euro
0,1 0,24 208
230
2 x 115 UTI0,1-115
4001708
82,20 0,30 1,50
0,2 0,45 380
400
  UTI0,2-115
4001709
97,60 0,70 3,51
0,315 0,83 415
440
  UTI0,315-115
4001710
111,30 1,10 5,52
0,5 1,5 460
480
  UTI0,5-115
4001711
136,40 1,30 6,52
0,63 1,6 500
525
  UTI0,63-115
4001712
158,80 2,10 10,53
0,8 2,5 550
575
  UTI0,8-115
4001713
181,00 2,30 11,53
1 3,7 600   UTI1,0-115
4001714
212,70 3,00 15,04
0,1 0,24   1 x 24 UTI0,1-24
4003509
74,50 0,30 1,50
0,2 0,45     UTI0,2-24
4003450
89,20 0,70 3,51
0,315 0,83     UTI0,315-24
4011506
109,20 1,10 5,52
0,5 1,5     UTI0,5-24
4004361
135,80 1,30 6,52
0,63 1,6     UTI0,63-24
4011507
158,80 2,10 10,53
0,8 2,5     UTI0,8-24
4011508
176,00 2,30 11,53
1 3,7     UTI1,0-24
4011509
211,40 3,00 15,04

1) The calculation method of the material price surcharge will be explained in Section 2.1 in the general conditions of busines
all dimensions in mm


UTI graphic - Single-phase multi-winding transformer
1) Max. space requirement
2) For type UTI0,1 earth connection downwards

Here is a hidden table in the mobile version. Click here to display it.
Type Total
weight
No-
load
losses
Short-
circuit
losses
Short-
circuit
voltage
Efficiency
factor
a b1 c1 b c b c e f ø g
  kg W W %         Us = 24V Us = 115V      
UTI0,1 2 8 11 7,5 0,84 85 74 76 89 93 89 93 64 61 4,8 x 8
UTI0,2 3 10 19 6,5 0,87 106 80 97 82 112 82 112 80 61 5,8 x 12
UTI0,315 4,3 15 23 5 0,89 121 86 106 88 124 88 124 90 68 5,8 x 12
UTI0,5 6,8 26 23 3,5 0,92 121 118 106 140 133 120 124 90 100 5,8 x 12
UTI0,63 7,7 25 32 3,8 0,92 151 104 132 122 159 107 150 122 82 7 x 15
UTI0,8 9,6 33 29 2,8 0,93 151 121 132 139 159 124 150 122 99 7 x 15
UTI1,0 13,4 46 30 2,1 0,93 151 147 132 165 159 150 150 122 125 7 x 15

Circuits of multi windings transformers

Circuits of multi windings transformers
a) primary voltage (V)

schaltung_mehrwicklungs_trafos2
b) secondary voltage (V), c) Brücke

Example:
If the transformers will be connected to a 460 V rated input voltage the terminals 1.4 and 1.8 must be connected.
If the transformers shall have 230 V rated output voltage, connect the terminals 2.3 and 2.4.
Phone Mail